LG Dryer Error Codes: d80, d90, d95, dE and tE1 Explained
The short answer: LG dryers report two families of codes, and they are easy to tell apart. Codes that start with d are about airflow and the door: d75, d80, d90 and d95 mean the exhaust duct is blocked by roughly that percentage, and dE means the door is not fully closed. Codes that start with t are about temperature sensing: tE1 and tE3 report a thermistor fault, and tE2 usually appears on steam cycles in cold weather. LG documents all of these in its dryer error code list, and every fix below is one LG itself suggests to owners.
In this guide
- What LG dryer codes are telling you
- The code table
- d75, d80, d90 and d95: a blocked exhaust duct
- The three places a blockage hides
- The Flow Sense bars
- dE and dE4: the door
- tE1 and tE3: the thermistor
- tE2: cold weather and steam cycles
- PF and other messages
- The reset that LG uses
- Safety
- When to call service
- Frequently asked questions
What LG dryer codes are telling you
LG equipped many of its dryers with a duct-blockage sensor, and that sensor is why so many LG codes are about airflow rather than heat. The dryer measures how easily air moves from the drum to the outside of the house. When the path narrows — lint in the filter, a crushed transition hose, a packed wall duct, a stuck exterior flap — the machine reports the restriction before the heat becomes a hazard.
The letter tells you the system:
- d codes — duct and door. A number after the d is a percentage of blockage; no number means the door.
- t codes — temperature sensing, usually the thermistor that measures the outgoing air.
- PF — a power interruption during the cycle.
Write the code down and note whether the dryer was hot, cold, or mid-load when it appeared. A d90 halfway through a heavy load of towels and a d90 at start-up point to different parts of the vent run.
The code table
| Code | What LG reports | First check | Typical outcome |
|---|---|---|---|
| d75 | Exhaust duct about 75% blocked | Lint filter, transition hose behind the dryer | Cleaning the filter and hose often clears it |
| d80 | Exhaust duct about 80% blocked (on gas dryers, possibly a gas supply problem) | Lint filter, hose, exterior flap; on gas models, the gas valve | Vent cleaning; gas supply check on gas models |
| d90 | Exhaust duct about 90% blocked | Full vent run, exterior hood | Professional duct cleaning is usually required |
| d95 | Exhaust duct about 95% blocked | Stop using the dryer; full vent inspection | Cleaning and possible repair before further use |
| dE / dE4 | Door error — door not completely closed | Lint filter pushed all the way in, clothing caught in the door | Close firmly and reset |
| tE1 / tE3 | Thermistor problem detected | Reset per LG’s procedure | Clears with reset or needs service |
| tE2 | Thermistor fault, normally in cold conditions | Vent for snow, ice, or a stuck exterior flap | Warm the dryer, run a steam cycle as LG describes |
| PF | Power failure during the cycle | Outlet, breaker, outage | Restart the cycle |
d75, d80, d90 and d95: a blocked exhaust duct
These four codes are one message at different severities. LG’s explanation is that the dryer’s hot, humid air has to vent somewhere, and the code tells you how much of the exhaust path is closed off — 75, 80, 90 or 95 percent. The dryer is not reporting a failed heater; it is reporting that heat is backing up, which is why LG treats duct cleaning as maintenance rather than repair.
Do not ignore the higher numbers. LG warns that using a dryer with a severely restricted exhaust can create an unsafe environment and advises not using the dryer until the exhaust system has been cleaned and repaired. That is a fire-safety instruction, not a performance note: lint is the material that most often ignites in dryer fires, and a blocked duct is how lint gets hot enough to do it.
One special case is worth knowing before you start pulling the machine out: LG notes that on gas dryers a d80 display may indicate a lack of gas supply to the unit rather than a duct blockage. If you have a gas dryer showing d80 and the vent is visibly clean, check that the gas valve at the wall is open before assuming the duct is at fault.
The three places a blockage hides
LG’s guidance divides the exhaust path into three zones, and working through them in this order is the fastest route to a clear vent.
1. Inside the dryer
- Empty the lint filter before or after every load. For a deeper clean, LG suggests washing the screen with warm water and a soft brush, drying it completely, and refitting it.
- Reduce the load size so air can pass through the clothes and move from the back of the drum to the front.
- With the power off, check the lint filter housing for a felt-like sheet of compacted lint that has slipped past the screen.
2. Behind the dryer
- Pull the machine out and inspect the transition duct between the dryer and the wall. It should not be crushed, dented, kinked, or compressed.
- The duct should run straight or in a gentle S curve. LG specifically warns against a hose coiled circle over circle like a spring, which traps lint at every loop.
- Check for holes and loose connections, and confirm the duct is rigid or semi-rigid metal rather than thin foil.
3. Outside the house
- Start an air-only cycle and go outside to the vent hood.
- Confirm the flappers open all the way. Lint can jam them partly shut, and a hood that never fully opens is a blockage in itself; LG’s advice is to replace a hood whose flappers cannot open.
- Clear visible lint around the hood and check that snow, ice, or a bird screen is not closing the outlet.
If all three zones are clear and the code returns, the blockage is inside the wall. That is the point where LG recommends a professional duct cleaning company, and it is worth asking them to report the total duct length, the number of 90-degree bends, and whether the run needs modification. Long runs and multiple elbows are the usual reason a dryer keeps reporting a restriction no matter how clean the visible parts are.
The Flow Sense bars
On models with the Flow Sense indicator, airflow restriction also shows as bars on the display. LG states that two or four bars mean the exhaust system is severely restricted. Treat the bars exactly like a d80 or above: check the filter, the transition duct and the exterior hood before running another load, and do not wait for a numbered code to appear.
dE and dE4: the door
dE means the dryer door is not completely closed. LG’s checklist is short and worth doing in order:
- Open the door and make sure the lint filter is pushed all the way into its slot. A filter that is half out holds the door off its seal.
- Check for clothing caught at the door opening, especially small items that fall forward as the drum stops.
- If the dryer is new, look for shipping damage — a bent door or frame — and contact the dealer rather than forcing it.
- Reset the machine: unplug it or trip the breaker, wait five seconds, restore power, close the door firmly, select any cycle and press start.
If dE returns after that, the door switch or its wiring needs service. Do not tape the door shut or wedge something against it to keep the dryer running; the door switch is also the interlock that stops the drum.
tE1 and tE3: the thermistor
tE1 and tE3 report a problem with the dryer’s thermistor, the sensor that reads the temperature of the air leaving the drum. LG’s fix is a factory-style reset, and it is the same procedure it recommends for most control-latched codes:
- Unplug the dryer, or switch off the breaker that feeds it.
- With the power off, press and hold the start/pause button for five seconds.
- Restore power and run a cycle.
If the code returns after a reset, LG’s guidance is that the unit may require repair service. That is the right call: a thermistor that reads wrong can let the dryer overheat, and the sensor is inside the cabinet.
tE2: cold weather and steam cycles
tE2 is the code that appears when the weather turns. LG explains that extra humidity in the drum during SteamFresh, Steam Sanitary or a steam option cools the duct faster than the sensor expects, which triggers the code. Cold outside air coming back through an open exterior vent makes it worse.
What to do, in LG’s order:
- Clean the lint filter and check the vent for snow, ice, or a flap that is stuck open or frozen.
- Warm the dryer by running it empty on a regular heated cycle for a few minutes before using the steam feature.
- Or select the steam cycle LG describes and raise the dryness or time setting until the display shows the bulky option, then start it.
On the vent side, make sure the exterior louvers and flaps operate freely and are not held open by lint, frost, or buildup. A flap that never closes lets cold air into the duct all winter, and tE2 will keep coming back. If the code persists after a reset, service is required.
PF and other messages
PF reports a power failure during the cycle — an outage, a tripped breaker, or someone unplugging the dryer. Restart the cycle. If it repeats with no outage, check that the dryer is on its own circuit: an electric dryer that shares a circuit, or that runs through an extension cord, will drop out under the load of the heating element.
If your model shows a code that is not in this table, use LG’s support library and select your exact model. Dryer code sets differ between vented, condensing and heat-pump models, and a code from another family can send you after the wrong part.
The reset that LG uses
Almost every LG procedure in this guide ends with the same reset. Learn it once:
- Power the dryer off at the panel.
- Unplug it, or switch the breaker off.
- With power removed, hold start/pause for five seconds.
- Restore power, close the door firmly, select a cycle, and start.
A code that survives this with a clean vent and a properly closed door is a component fault, not a user error.
Safety
- Stop using a dryer that reports d90 or d95 until the exhaust path is cleared. LG explicitly advises against running it.
- Unplug before touching the duct or any panel. Electric dryers run on 240 volts.
- Do not substitute plastic or foil duct for metal duct when replacing a crushed hose; it traps lint and crushes again.
- Do not dry items that have been in contact with gasoline, oil, or solvents, and do not leave the house with the dryer running.
- If the dryer overheats, smells scorched, or the exterior hood is hot to the touch, stop, unplug, and have the vent and the dryer inspected.
When to call service
Call LG service, or a vent specialist for the duct work, when a d-code returns after all three zones have been cleaned, when a t-code returns after a reset, when dE returns with a clean door area, or when the dryer runs but the drum air stays cold with no code at all. For a blockage inside the wall, a duct cleaning company is the right first call — LG recommends asking them to check lint accumulation, total vent length, the number of 90-degree bends, and whether the run needs modification.
Frequently asked questions
Does a d90 code mean the dryer is broken?
Usually not. It means the exhaust path is about 90% restricted. The dryer’s sensor is doing its job. Clean the filter, the transition duct and the exterior hood, and the code normally stops appearing.
Why does my LG dryer show d80 only on gas models?
LG notes that on gas dryers d80 can indicate a lack of gas supplied to the unit in addition to a duct restriction. If the vent is clean, check that the gas valve is open and that other gas appliances in the house are working.
Can I keep running the dryer with d75 showing?
It is better not to. A 75% restriction is already substantial, and the restriction grows as more lint packs into the same spot. Clean it now rather than at d95.
Why does the tE2 code appear only in winter?
Cold air entering through the exterior vent cools the duct faster than the sensor expects, and steam cycles add humidity that makes the effect stronger. Check the flap and louvers, warm the dryer on a regular cycle first, and the code usually stays away.
How often should the vent be cleaned on an LG dryer?
Empty the lint filter every load, and clean the full vent run at least once a year — more often for a long duct, a household with pets, or a dryer that reports airflow codes. The annual cleaning is the same recommendation the CPSC and NFPA make for any dryer.
My dryer shows a code that is not listed anywhere. What should I do?
Look up your exact model in LG’s support library before acting. Vented, condensing and heat-pump dryers use different code sets, and the same letters can mean different things across them.